Specifications of the data logger MicroLog function
- measuring the relative
humidity of air and air temperature
- internal memory for
up to 16,000 measured values (8,000 records with date, time, relative humidity of air
and air temperature)
- limiting-value monitoring
for both measured values
input
- internal sensors for
relative humidity of air and air temperature
- measuring range relative humidity of air 0 to 90 %
relative humidity (resolution 0.5 % relative humidity, accuracy ± 3 % relative humidity)
- measuring range air temperature -30
to +50 °C (resolution 0.5 °C, accuracy ± 1 K)
configuration
- with software MicroLab
(included in delivery)
- adjustable period for storing
the measured values 10 seconds to 2 hours
- adjustable limiting-values
for both measured values
display and operation
- LC - display 2 digits
for indication of the actual values or MIN/MAX values
- two key operation for
communication and display options
(data are stored so that they can not be interfered with or changed)
communication
- RS232-standard interface
- infrared interface
power supply
- internal lithium-battery
3.6 V TL5101, changeable
- battery live approx.
2 years
housing
- plastic; protection grade
IP65
- dimensions diameter
72 mm x 23 mm; weight 55 g